MonoSeal Cold-Applied Pure Polyurea Waterproofing Membrane
MonoSeal is a cold-applied pure polyurea waterproofing membrane using 3GTX technology. No primary reinforcement fleece required. Applied by hand to form a seamless waterproofing membrane over suitable prepared substrates. Substrate condition, moisture, preparation, detailing and system compatibility must be confirmed before specification.
Chemistry
Pure Polyurea — 3GTX Technology
Elongation
1,530% — DIN 53504
Application
Cold-Applied — Hand Applied
Warranty
Project-Specific — Qualifying Installations
MonoSeal Quick Answers
Forti Nova works directly with Prokol as an Outreach Partner, supporting MonoSeal projects through assessment, specification guidance, product supply, training and warranty-pathway coordination.
What it is
What is MonoSeal?
MonoSeal is a cold-applied pure polyurea waterproofing membrane using 3GTX technology. Applied by hand to form a seamless bonded layer over suitable prepared substrates. Documented elongation of 1,530% (DIN 53504). No reinforcement fleece required for the primary membrane. Vapour permeable.
What it is used for
What is MonoSeal used for?
It may be used for suitable flat and slightly pitched roofs, balconies, terraces, walkways and refurbishment overlays where a cold-applied, hand-applied liquid membrane is appropriate and where open flames are prohibited.
What it is not
What is MonoSeal not designed to do?
It is not a structural repair system, traffic-bearing finish or automatic solution for saturated insulation, severe substrate failure, unstable substrates or unresolved trapped moisture.
Potential substrates
Which substrates may be suitable for MonoSeal?
Potential substrates may include prepared concrete, masonry, bituminous surfaces, timber, and compatible existing coatings, subject to condition, preparation, adhesion and primer assessment.
Before specifying
What should be assessed before specifying MonoSeal?
Review substrate condition, moisture, drainage, movement, contamination, existing coatings and any evidence of structural or roof build-up failure. Environmental conditions and product temperature handling must also be confirmed.
Who specifies and applies
Who should specify or apply MonoSeal?
Specification and application should be undertaken by competent project professionals and trained applicators working to the confirmed system requirements, with technical support where required.
Before use
What must be confirmed before MonoSeal is used?
Confirm substrate compatibility, preparation, primer requirements, membrane build-up, weather conditions (RH below 85%), product temperature (15–25°C), detailing and the project-specific warranty pathway.
Related MonoSeal Guidance
Seamless Polyurea Waterproofing Without Open Flame
MonoSeal is commonly considered where cold-applied hand application and close control around details, balconies and roof surfaces are required, particularly where open flames are prohibited. 3GTX technology eliminates the need for primary reinforcement fleece — reducing application complexity and programme time on suitable projects.
Flat Roofs & Slightly Pitched Surfaces
Seamless waterproofing membrane for commercial roofing refurbishment and overlay applications. Cold-applied hand application appropriate for a wide range of access conditions.
Balconies, Terraces & Walkways
Considered for balconies, terraces and pedestrian walkways where open-flame application is prohibited. Suitability for regular pedestrian use and any required wearing finish must be confirmed within the complete project specification.
Complex Details & Geometries
Documented elongation of 1,530% (DIN 53504) supports detailing around complex geometries. Hand application allows close control at penetrations, upstands and junctions.
Refurbishment Overlays
May be considered as a refurbishment overlay over suitable existing waterproofing systems subject to substrate condition, adhesion assessment and preparation confirmation.
MonoSeal or Rocathaan HotSpray?
MonoSeal — Cold-Applied Hand Application
Generally considered for suitable roofs, balconies, terraces, walkways and complex details where controlled hand application is appropriate and open-flame application is prohibited. Substrate, primer, detailing and system build-up remain project-specific.
Rocathaan HotSpray — Specialist Spray Application
Specialist spray-applied pure-polyurea membrane used where rapid application and rapid curing are required. It requires specialist plural-component equipment, trained application and a project-specific specification. The complete traffic-rated system and wearing-layer requirements must be confirmed separately.
3GTX Technology — No Primary Reinforcement Fleece
MonoSeal's 3GTX formulation eliminates the need for primary reinforcement fleece within the documented system, reducing application steps and programme complexity. Local detailing at joints, vertical parts and overlaps may still apply. Confirm all detailing requirements with the Forti Nova technical team before specification. Flat Roof Waterproofing Guide →
Is MonoSeal suitable for your project?
Suitability depends on substrate condition, moisture, drainage, structural integrity and system compatibility. Visual inspection alone is insufficient. A pre-specification assessment is required before MonoSeal can be correctly specified.
Assessment Required
Adhesion confirmation, substrate condition verification and moisture assessment are required before MonoSeal can be specified. Product temperature (15–25°C) must be confirmed before mixing.
Potentially Suitable Applications
Subject to condition, preparation, adhesion and primer assessment for the confirmed substrate type.
- Flat and slightly pitched roofs — condition assessed
- Balconies, terraces and walkways — wearing finish to be confirmed within project specification
- Refurbishment overlays — sound bonded substrate
- Complex details and geometries — hand applied
- Sites where open-flame application is prohibited
Not Suitable For
- Vehicle traffic or car park decks — use traffic-bearing system
- Substrates with elevated moisture — assess and confirm threshold
- Structurally unsound substrates
- Active cracking or structural movement without project-specific detailing
- Concealing saturated insulation or unresolved trapped moisture
- Application when RH exceeds 85% or product below 15°C
Survey Requirements
- Moisture assessment using appropriate project method
- Substrate adhesion and contamination assessment
- Drainage fall and outlet condition check
- Upstand height and perimeter detailing review
- Existing coating identification and compatibility
Cannot Assess Visually
- Sub-surface moisture content
- Insulation saturation
- Deck condition beneath membrane
- Chemical compatibility with existing coatings
- Drainage capacity under load
Common Failure Indicators
Blistering after application
Elevated substrate moisture at application. Membrane separated from substrate by vapour pressure.
Required Response
Strip blistered areas, dry substrate, retest moisture and reapply within confirmed conditions.
Edge lifting at perimeters
Inadequate primer or contaminated termination. Detailing insufficient at edges and upstands.
Required Response
Lift and reterminate edges. Confirm primer compatibility and detailing specification.
Mixing failure / poor cure
Product below 15°C before mixing — causes high viscosity and poor mixing. Cold temperature application without conditioning.
Required Response
Condition product to 15–25°C before mixing. Verify environmental conditions comply with TDS.
Specification Data
- Chemistry
- Cold-applied pure polyurea — 3GTX technology, two-component system
- Elongation
- 1,530% — DIN 53504
- Vapour Permeability
- Vapour permeable — µ value 1,000 per PDS
- Coverage
- 1.5–2.5 kg/m²/layer, situation dependent — confirm current TDS
- Walkability
- Approx. 2–4 hours at 20°C / 65% RH — indicative, conditions-dependent
- BRoof Classification
- EN 13501-5 BRoof(t1) and BRoof(t4) — Warrington Fire Gent. Apply to exact tested build-up only.
Application Methods & Preparation
Applied by roller, brush, trowel or squeegee. No specialist spray equipment required. 3GTX technology eliminates the need for primary reinforcement fleece, reducing application steps. Preparation depends on the substrate and its condition — surfaces must be assessed for adhesion, contamination, moisture, loose material and existing coatings before application.
Note: Primer requirements must be confirmed during project assessment for each substrate type — they cannot be assumed in advance. Product must be conditioned to 15–25°C before mixing.
Environmental Controls
Application requires suitable dry conditions with relative humidity below 85%. At low temperatures, cold product results in high viscosity and poor mixing — both components must be conditioned to 15–25°C before use. Temperature, humidity and rainfall risk must be checked against the current technical documentation before work begins. Application records must be maintained throughout the project.
Warranty
Project-Specific Warranty on Qualifying Installations
Available on qualifying installations subject to the confirmed specification, preparation, application and manufacturer acceptance. All of the following conditions apply.
Substrate moisture confirmed below threshold
Moisture must be tested immediately before application — not at survey stage weeks earlier. Assessment method must be appropriate to the substrate and project.
Trained approved applicator
Warranty pathway requires trained and approved contractor application.
Product temperature 15–25°C before mixing
Cold product causes high viscosity and poor mixing. Conditioning must be confirmed before mixing commences.
Detailing complete at all terminations
Joints, penetrations, upstands and vertical parts detailed to the confirmed system specification using MonoSeal Detail where required.
Full system build-up maintained
Coverage rate, coat sequence and full system specification must comply with the confirmed TDS for the project.
BRoof classification — exact build-up confirmed
Where fire classification is required, EN 13501-5 BRoof(t1) or BRoof(t4) applies only to the exact tested construction. Confirm with technical team before specification.
Gallery & Documents
MonoSeal project imagery and approved technical documentation.

MonoSeal polyurea membrane application — cold-applied flat roof waterproofing by Forti Nova

MonoSeal roof detailing — 3GTX cold-applied polyurea membrane

MonoSeal completed flat roof — Prokol polyurea waterproofing system

MonoSeal balcony waterproofing application — cold-applied membrane

MonoSeal flat roof gutter detail — polyurea membrane detailing

MonoSeal completed flat roof — Forti Nova certified installation
Technical Documentation
MonoSeal Technical Documentation — Available on Request
Technical Data Sheets, Safety Data Sheets and application guidance are available directly from our technical team. Email Info@FortiNova.co.uk with the product name and document type required.
MonoSeal — Technical Information
MonoSeal — Product Data Sheet
Available to download. Confirm current version before specification.
MonoSeal Base — Safety Data Sheet
Available to download.
MonoSeal Hardener — Safety Data Sheet
Available to download.
Application and Detailing Guidance
Project-specific guidance available on request — contact technical team.
Related Systems
Important: All technical datasheets and safety documentation must be reviewed prior to specification and installation. Any warranty is project-specific and conditional on full compliance with manufacturer application requirements and trained approved applicator installation.
MonoSeal Common Questions
Specification intelligence for contractors, specifiers and facilities managers.
Discuss a MonoSeal Project
Submit your project details for technical assessment, specification guidance and support from the Forti Nova team.
Technical Assessment
Substrate and system suitability reviewed by our technical team before specification.
Specification Guidance
Preparation requirements, primer assessment, system build-up and application conditions confirmed for your project.
Warranty-Pathway Coordination
Warranty conditions and the approved applicator pathway confirmed before work begins.
MonoSeal Applicator Training — Blackburn, UK
Hands-On Product Training
Forti Nova hosts comprehensive MonoSeal application training at our Blackburn facility. Practical, hands-on instruction covering substrate preparation, mixing ratios, application techniques, detailing, and quality control. Designed for contractors and applicators seeking specification-grade installation capability.
- Substrate assessment and preparation protocols
- System-specific mixing and application
- Detailing for complex geometries
- Quality control and inspection procedures
- Environmental constraints and cure management
Approved Applicator Network
Forti Nova maintains a network of trained MonoSeal applicators across the UK. Specifiers and main contractors can request approved applicators for project tender and execution. Training ensures consistent application quality, specification compliance, and warranty validation support.
For Contractors
Become a Forti Nova approved applicator. Training, technical support, and project referral network access.
For Specifiers
Request approved applicators for tender lists. Verified training, technical capability, and warranty compliance support.
Training & Specification Support
Use the contact wizard to request training, join the applicator network, or specify MonoSeal for your project.
Related Applications & Prokol Systems
Is MonoSeal suitable for your project?
Request a technical assessment to verify system suitability and specification.